<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Refrigeration Technology</journal-id><journal-title-group><journal-title xml:lang="en">Refrigeration Technology</journal-title><trans-title-group xml:lang="ru"><trans-title>Холодильная техника</trans-title></trans-title-group><trans-title-group xml:lang="zh"><trans-title>制冷技术</trans-title></trans-title-group></journal-title-group><issn publication-format="print">0023-124X</issn><issn publication-format="electronic">2782-4241</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">101215</article-id><article-id pub-id-type="doi">10.17816/RF101215</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Статьи</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Features of designing air conditioning systems according to new building codes</article-title><trans-title-group xml:lang="ru"><trans-title>Особенности проектирования систем кондиционирования воздуха по новым строительным нормативам</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Kokorin</surname><given-names>O. Ya.</given-names></name><name xml:lang="ru"><surname>Кокорин</surname><given-names>О. Я.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MGSU</p></bio><bio xml:lang="ru"><p><italic>МГСУ</italic></p></bio><email>info@eco-vector.com</email><xref ref-type="aff" rid="aff1"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Doctor of Engineering, Sciences, Prof.</institution></aff><aff><institution xml:lang="ru">Д-Р техн, наук, проф</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2004-09-15" publication-format="electronic"><day>15</day><month>09</month><year>2004</year></pub-date><volume>93</volume><issue>9</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>34</fpage><lpage>38</lpage><history><date date-type="received" iso-8601-date="2022-02-20"><day>20</day><month>02</month><year>2022</year></date><date date-type="accepted" iso-8601-date="2022-02-20"><day>20</day><month>02</month><year>2022</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2022, Kokorin O.Y.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2022, Кокорин О.Я.</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="en">Kokorin O.Y.</copyright-holder><copyright-holder xml:lang="ru">Кокорин О.Я.</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://freezetech.ru/0023-124X/article/view/101215">https://freezetech.ru/0023-124X/article/view/101215</self-uri><abstract xml:lang="en"><p>New standards with regards to systems of heating, ventilation, air conditioning and building climatology introduce considerable changes when choosing the regimes of preparation ofthe conditioned air. A higher humidity of the outside air design parameters has required obligatory use of the regimes of refrigeration and drying of the inlet outside air. Based on the use of York equipment, energy efficient air conditioning systems are being developed.</p></abstract><trans-abstract xml:lang="ru"><p>В течение многих десятилетий при проектировании систем отопления, вентиляции и кондиционирования воздуха пользовались СНиП, в которых даны таблицы расчетных параметров наружного воздуха А и Б для холодного и теплого периодов года. С января 2004 г. прежние СНиП были отменены и стал действовать новый нормативный документ [2], в котором таблицы расчетных климатических условий отсутствуют.</p></trans-abstract><kwd-group xml:lang="en"><kwd>heat extracting heat exchanger</kwd><kwd>supply air</kwd><kwd>exploitation</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>теплоизвлекающий теплообменник</kwd><kwd>приточнскый наружный воздух</kwd><kwd>эксплуатация</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Кокорин О.Я. Современные системы кондиционирования воздуха. -М.: Физматлит, 2003.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>СНиП 41-01-2003. Отопление, вентиляция и кондиционирование. Госстрой России, ФГУП ЦПП, 2004.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>СНиП 23-01-99. Строительная климатология. Госстрой России, ГУП ЦПП, 2000.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Фирма “Йорк”. Каталог на оборудование для кондиционирования воздуха и холодоснабжения (высылается фирмой по запросам).</mixed-citation></ref></ref-list></back></article>
