<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Refrigeration Technology</journal-id><journal-title-group><journal-title xml:lang="en">Refrigeration Technology</journal-title><trans-title-group xml:lang="ru"><trans-title>Холодильная техника</trans-title></trans-title-group><trans-title-group xml:lang="zh"><trans-title>制冷技术</trans-title></trans-title-group></journal-title-group><issn publication-format="print">0023-124X</issn><issn publication-format="electronic">2782-4241</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">98355</article-id><article-id pub-id-type="doi">10.17816/RF98355</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Статьи</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Sistema ventilyatsii i konditsionirovaniya Bol'shogo zala Moskovskoy konservatorii</article-title><trans-title-group xml:lang="ru"><trans-title>Система вентиляции и кондиционирования Большого зала Московской консерватории</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Kolosov</surname><given-names>Mikhail Anatol'evich</given-names></name><name xml:lang="ru"><surname>Колосов</surname><given-names>Михаил Анатольевич</given-names></name></name-alternatives><bio xml:lang="ru"><p>Канд. техн. наук</p></bio><email>kolosov@himholod.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Egorov</surname><given-names>K. S</given-names></name><name xml:lang="ru"><surname>Егоров</surname><given-names>К. С</given-names></name></name-alternatives><bio xml:lang="ru"><p>Канд. техн. наук</p></bio><email>blackbird@mail.ru</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en"></institution></aff><aff><institution xml:lang="ru">ООО «НПФ «ХИМХОЛОДСЕРВИС»</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en"></institution></aff><aff><institution xml:lang="ru">МГТУ им. Н.Э.Баумана</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2012-10-15" publication-format="electronic"><day>15</day><month>10</month><year>2012</year></pub-date><volume>101</volume><issue>10</issue><issue-title xml:lang="en">NO10 (2012)</issue-title><issue-title xml:lang="ru">№10 (2012)</issue-title><fpage>12</fpage><lpage>14</lpage><history><date date-type="received" iso-8601-date="2022-01-25"><day>25</day><month>01</month><year>2022</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2012, Kolosov M.A., Egorov K.S.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2012, Колосов М.А., Егоров К.С.</copyright-statement><copyright-year>2012</copyright-year><copyright-holder xml:lang="en">Kolosov M.A., Egorov K.S.</copyright-holder><copyright-holder xml:lang="ru">Колосов М.А., Егоров К.С.</copyright-holder><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://creativecommons.org/licenses/by/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://freezetech.ru/0023-124X/article/view/98355">https://freezetech.ru/0023-124X/article/view/98355</self-uri><abstract xml:lang="ru"><p>Система вентиляции и кондиционирования Большого зала консерватории, являясь частью всего проекта системы кондиционирования и вентиляции Московской консерватории, выполненного ГУП «Моспроект-4», имеет много особенностей, исследование которых было выполнено в сотрудничестве НИИ «ЭМ» МГТУ им. Н.Э.Баумана и НПФ «ХИМХОЛОДСЕРВИС» методами математического моделирования. В этой части статьи представлены основные результаты моделирования процессов вентиляции в пространстве сцены для двух вариантов подачи свежего воздуха. Моделирование позволило доказать преимущества модернизированного варианта воздухораспределения на сцене и оптимизировать положение и высоту размещения распределительных решеток. В результате верхний уровень скоростей воздуха на сцене был снижен с ~2 до ~0,5 м/с и было обеспечено равномерное снабжение ее свежим воздухом при скорости 0,1...0,05 м/с, что соответствует санитарным нормам и условиям комфорта.</p></abstract><kwd-group xml:lang="ru"><kwd>воздухораспределение</kwd><kwd>пространство сцены</kwd><kwd>вентиляция</kwd><kwd>эпюры скоростей</kwd></kwd-group></article-meta></front><body></body><back><ref-list/></back></article>
