Energy-saving air conditioning systems of the ice field zone of artificial skating-rink premises



如何引用文章

全文:

详细

The paper deals with the use of refrigerated dehumidifiers for the preparation of sanitary norm of incoming outside air to create an energy-saving air conditioning system for the ice field zone of closed artificial skating-rinks. Three skating-rink operation modes are considered: ice hockey, figure skating and skating of visitors. A drying unit ST 215B is used. The drying process is presented on I-d diagram. Electrical energy costs to be observed for air conditioning system including driers have been calculated; they turned out to be 5-7 times lower than traditional ones depending on the operation mode should be of the skating-rink. With year-round operation of the skating rink, an air cooler is installed before the air drier.

作者简介

O Kokorin

MGSU

Д-р техн. наук; МГСУ; MGSU

N Tovaras

OOO NPF Himholodservice

канд. техн. наук; ООО «НПФ Химхолодсервис»; OOO NPF Himholodservice

A Inkov

OOO Ecoterm

канд. техн. наук; ООО «Экотерм»; OOO Ecoterm

参考

  1. Кокорин О.Я. Энергосберегающие системы кондиционирования воздуха. - М.: ООО «ЛЭС», 2007.
  2. Осушители воздуха «PoLar Bear». Каталог фирмы «Арктика», 2007.
  3. СНиП 23-01-99. Строительная климатология. - М.: Госстрой России, 2000.