Trebovaniya k mikroklimatu v TsOD: osnovnye ponyatiya, razlichnye standarty, osobennosti ikh primeneniya



Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

The work is dedicated to the comparison of the domestic and foreign standard documentation in the field of maintaining the microclimate in data processing centers (DC). The paper examines admissible and optimal climatic ranges; also the analysis of trends to moderate requirements for the control accuracy of given climatic parameters in DPC was carried out. The study defines the algorithm of actions of a designengineer to choose correct calculation values of temperature, humidity and other parameters of the microclimate inside DPC. The most important steps when defining the calculation parameters that require the specific attention and qualification are marked out. It is shown that in spite of the foregrounding, the Russian design standards became oldfashion in comparison with foreign ones, as they were elaborated for application in data processing technique that differed principally from modern one as regards type and construction. Therefore the analysis of some foreign standards in this field as well as the research of recommendations in them were carried out with the aim to apply them in the projects of the Russian DPC to increase their manufacturability and saving energy that is needed for supplying the air conditioning systems in DPC.

Keywords

Full Text

Restricted Access

References

  1. Сет Ллойд. Программируя вселенную. Квантовый компьютер и будущее науки. - М.: Альпина нонфикшн, 2014. - 48 с.
  2. СН 512-78. Инструкция по проектированию зданий и помещений для электронновычислительных машин. - ЦНИПИАСС Госстроя СССР, 1979. - 2,3,11 с.
  3. Хайретдинов Р. Проблемы построения систем кондиционирования воздуха и вентиляции в серверных помещениях и помещениях Центров обработки данных // Холодильный бизнес. 2009. № 8. С. 17.
  4. Heat Density Trends in Data Processing Computer Systems and Telecommunications Equipment. - The Uptime Institute, 2005.
  5. Thermal Guidelines for Data Processing Environments - Expanded Data Center Classes and Usage Guidance. - ASHRAE TC 9.9, 2011. - 2-10, 12-29 c.
  6. ТIA - 942. Telecommunications Infrastructure Standard for Data Centers. - TIA, 2012. - 3 c.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2017 Kosenko A.A.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies